130 GHz S-parameter measurement setup (FormFactor)
APPLICATION / 03 PA & LARGE-SIGNAL

On-Wafer Load-Pull

Vary the output impedance of PAs and power transistors, measure power, gain and efficiency, and find the best match.

Industries
6
Measurement tasks
14
Related devices
5G FR2 / 6G PAsGaN/GaAs HEMTsSiGe/CMOS PAsSatellite & radar transmitters
01 / APPLICATION

Measurement applications

01

Power and efficiency contours

Move the impedance with tuners and map power, gain and PAE on the Smith chart.

02

Harmonic tuning

Tune 2nd and 3rd harmonic impedances to improve efficiency.

03

Modulated-signal load-pull

With the tuner on the probe the delay is short, so wideband modulated signals can be used.

04

Probe-tip and tuner calibration

Calibrate on-wafer to the probe tips, and characterize tuner loss with a coaxial calibration to the tuner input.

02 / SETUP

The setup at a glance

PNA-X (N524xB)PNA-X / N5291ASource & receivers
Source tunerFocus · MauryThird-party
Infinity ProbeRF probeDirect to tuner
DUTPA · transistor
Infinity ProbeRF probeDirect to tuner
Load tunerFocus · MauryThird-party
EPS200MMWAll on the probe stationEPS200MMW · MPS150 · PM8
PNA-X / N5291ASource & receiversPNA-X (N524xB)
Source tunerFocus · MauryThird-party
EPS200MMWAll on the probe stationEPS200MMW · MPS150 · PM8
RF probeDirect to tunerInfinity Probe
DUTPA · transistor
RF probeDirect to tunerInfinity Probe
Load tunerFocus · MauryThird-party

DSF supplies the station, probes, calibration and Keysight instruments; tuners and load-pull software come from the Focus or Maury system.

03 / WHY

Why this setup

04 / DSF SOLUTION

DSF solution setup

DSF SYSTEMFormFactorKeysightGoreThird-partyFocusMaury

05 / TECH GUIDE

From the Tech Guide

See the related videos and FAQ for setup and calibration guidance.

INDUSTRIES FOR THIS TASK
NEXT / DSF SOLUTION

Talk to us about
this setup.

SOURCES
FormFactor — Advanced mm-Wave Load-Pull Measurements ↗FormFactor IMS-K-Load-Pull (Keysight + Focus) ↗FormFactor + Maury on-wafer load-pull (2025-06-19) ↗FormFactor + Focus + Keysight mm-wave load-pull (2023-10-05) ↗FormFactor MeasureOne — RF Tuning & Load-Pull ↗FormFactor MPS150 ↗Keysight + Focus — On-Wafer 110 GHz Load Pull for 5G ↗Maury — Device Characterization Solutions ↗Focus — 120 GHz Harmonic Load Pull ↗

Industry groupings are examples of where these measurements are used and do not imply customers or references. Maury Microwave, Focus Microwaves and VDI products are not supplied by DSF; they are shown as systems that work with DSF stations and probes. Product names are trademarks of their owners; figures follow the cited sources.