Power and efficiency contours
Move the impedance with tuners and map power, gain and PAE on the Smith chart.

Vary the output impedance of PAs and power transistors, measure power, gain and efficiency, and find the best match.
Move the impedance with tuners and map power, gain and PAE on the Smith chart.
Tune 2nd and 3rd harmonic impedances to improve efficiency.
With the tuner on the probe the delay is short, so wideband modulated signals can be used.
Calibrate on-wafer to the probe tips, and characterize tuner loss with a coaxial calibration to the tuner input.
PNA-X / N5291ASource & receivers
RF probeDirect to tuner
RF probeDirect to tuner
All on the probe stationEPS200MMW · MPS150 · PM8
All on the probe stationEPS200MMW · MPS150 · PM8

DSF supplies the station, probes, calibration and Keysight instruments; tuners and load-pull software come from the Focus or Maury system.
In a FormFactor example (SUMMIT200 + Infinity + Keysight N5291A) the direct-tuner setup reached Γmax 0.84 at 28 GHz, 0.79 at 50 GHz and 0.70 at 96 GHz.
FormFactor — Advanced mm-Wave Load-Pull Measurements ↗FormFactor offers IMS-K-Load-Pull with Keysight VNAs and Focus tuners, and a joint solution that mounts Maury Nano tuners on its probe arms.
FormFactor IMS-K-Load-Pull (Keysight + Focus) ↗The FormFactor–Maury solution also works on MPS150 and PM8, not only SUMMIT200.
FormFactor + Maury on-wafer load-pull (2025-06-19) ↗See the related videos and FAQ for setup and calibration guidance.
Industry groupings are examples of where these measurements are used and do not imply customers or references. Maury Microwave, Focus Microwaves and VDI products are not supplied by DSF; they are shown as systems that work with DSF stations and probes. Product names are trademarks of their owners; figures follow the cited sources.